EUROCODE 1 · EN 1991-1-3 + EN 1991-1-4

EN 1991 specifier tool

Pick your country and the wind / snow zone for the install site. The tool computes site reference wind pressure (qb) and characteristic snow load (sk) per Eurocode 1 national annexes, then checks each VisioMod fence and railing system against its rated envelope. For permit-level documentation always commission a site-specific structural calc.

Country
Pick a continent
NORTH AMERICAdata coming soonSOUTH AMERICAdata coming soonEUROPE29 citiesAFRICAdata coming soonMIDDLE EASTdata coming soonASIAdata coming soonOCEANIAdata coming soon

EN 1991 national annexes cover EU + EEA. For sites outside Europe — ASCE 7-22 (US), AS/NZS 1170 (AU/NZ), NBCC (CA), GB 50009 (CN), TS 498 (TR), SP 20.13330 (RU) — contact our engineering team.

SITE qb0.39 kN/m²Germany · Wind zone 2 (most of central DE)Snow 0.81 kN/m²
Site presets

Site loads & product compliance

Site reference wind pressure qb

0.391 kN/m²

vb,0 = 25 m/s

Site characteristic snow load sk

0.81 kN/m²

Productqb maxWind marginsk maxSnow marginVerdict
VisioMod Lineo — horizontal slat fence0.98+60%1.40+42%OK
VisioMod Verto — vertical slat fence0.98+60%1.40+42%OK
VisioMod Bosco — WPC + aluminium fence0.98+60%1.40+42%OK
VisioMod Cristallo — tempered glass fence1.12+65%1.60+49%OK
VisioMod Porta — gate program0.98+60%1.40+42%OK
VisioMod Modulo — post system1.12+65%1.40+42%OK

qb (kN/m²) = ½ × 1.25 × vb,0² · margin = (qbMax − siteQb) / qbMax · sk margin analogous.

→ Browse the structural standards (EN 1991-1-3 + 1991-1-4, EN 1090) we comply with.

Pre-fill a quote with this scenario
Your country and wind/snow zones flow through to the quote form.
Get a tailored quote

METHOD

Wind reference pressure qb = ½ × ρ × vb,0² (ρ = 1.25 kg/m³). Site qb is the value at 10 m height, terrain category II (open, low vegetation). Fence height drives the actual pressure on the panel: at 1100 mm height the boundary-layer reduction lowers qb at the panel face by ~30 % vs the 10 m reference; at 2200 mm the reduction is ~10 %. The compliance check below uses 10 m reference qb — for tall fences in exposed terrain category 0 (coastal first-line) apply ce(z) and cprob factors per the national annex.

Snow load primarily affects sliding-gate canopy covers and any horizontal infill above 30 mm depth. For vertical fence panels and glass railings the dominant action is wind. The matrix below reports the rated snow envelope for product family completeness; for vertical surfaces snow margin can be ignored.

This tool returns characteristic / typical zone values. For permit submissions, your structural engineer must apply altitude correction (where sk depends on elevation), local exposure coefficients, and the partial safety factors of EN 1990 / national annex.